Search results for " Stress Analysis"

showing 10 items of 57 documents

Quantitative thermoelastic stress analysis by means of low-cost setups

2020

Abstract A low-cost Thermoelastic Stress Analysis (TSA) experimental setup is proposed which uses an ordinary micro-bolometer and in-house developed signal processing scripts. The setup is evaluated by analysing the thermoelastic signal from a tensile and a SENT specimen made of stainless steel AISI 304L, and the bolometer performances are compared with those of a state of the art photon detector. Signal processing is based on off-line cross-correlation, using a self-reference signal which is retrieved from the acquired thermal data. Procedures are in particular developed to recognise, quantify and correct errors due to spectral leakage and loss of streamed frames. The thermoelastic signal …

Signal processingMaterials scienceMicro-bolometersAcoustics/dk/atira/pure/subjectarea/asjc/2500/2504/dk/atira/pure/subjectarea/asjc/2200/2208Crack-growth monitoringThermoelastic stress analysis02 engineering and technologyFatigue testing01 natural sciencesSignallaw.invention010309 opticsSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineThermoelastic dampingData acquisitionlaw0103 physical sciencesCalibrationElectrical and Electronic EngineeringSpectral leakageStress intensity factorSignal processing/dk/atira/pure/subjectarea/asjc/3100/3107Mechanical EngineeringBolometer021001 nanoscience & nanotechnologyAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsIR-thermography/dk/atira/pure/subjectarea/asjc/2200/22100210 nano-technology
researchProduct

Water diffusion and swelling stresses in ionizing radiation cured epoxy matrices

2017

Abstract In this work a DGEBF epoxy monomer was cured by electron beam radiation in the presence of an iodonium salt and the obtained system was hydrothermally aged as such and also after a thermal treatment, in order to obtain two systems having different uniformity in the cross-linking degree. On both systems, the transient stress field arising from swelling was measured and monitored by an optical Photoelastic technique and the results were commented with reference to a thermally cured epoxy system containing the same monomer and already discussed in a previous work. Beam samples with identical dimensions, obtained from the irradiated systems, have been aged at 80 °C in water, and charac…

Materials scienceDynamic mechanical thermal analysis Epoxy resins Hydrothermal aging Photoelastic Stress Analysis Radiation curing SwellingPolymers and Plastics02 engineering and technologyThermal treatment010402 general chemistry01 natural sciencesMaterials ChemistrymedicineIrradiationComposite materialCuring (chemistry)EpoxyDynamic mechanical analysis021001 nanoscience & nanotechnologyCondensed Matter Physics0104 chemical sciencesStress fieldMechanics of Materialsvisual_artvisual_art.visual_art_mediumGravimetric analysisSettore CHIM/07 - Fondamenti Chimici Delle TecnologieSwellingmedicine.symptom0210 nano-technology
researchProduct

Photoelastic stress analysis assisted evaluation of fracture toughness in hydrothermally aged epoxies

2014

The present work has investigated the fracture toughness of a model DGEBA epoxy system subject to Hidro-Thermal aging. A Photoelastic Stress Analysis technique has been implemented, showing the evolution of stresses arising throughout the water uptake process due to the non-uniform swelling of the material. Gravimetric and Dynamic Mechanical Thermal Analyses have further complemented the characterization, showing the onset of plasticization effects with aging. The correlation of all previous characterizations has allowed to conclude that an increase of KIC fracture toughness is obtained at the fully saturated condition. In particular Photoelasticity has also revealed the onset of relevant s…

ToughnessMaterials scienceAbsorption of waterlcsh:Mechanical engineering and machinerylcsh:TA630-695Stress (mechanics)Thermosetting ResinSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineFracture toughnessFracture Toughnessmedicinelcsh:TJ1-1570Hydrothermal AgingComposite materialPhotoelasticityFracture Toughness; Hydrothermal Aging; Thermosetting Resin; Swelling Stresses; Photoelastic Stress Analysis.Mechanical EngineeringEpoxylcsh:Structural engineering (General)Fracture ToughneSwelling StresseSwelling StressesMechanics of Materialsvisual_artvisual_art.visual_art_mediumPhotoelastic Stress Analysis.Gravimetric analysisSettore CHIM/07 - Fondamenti Chimici Delle TecnologieSwellingmedicine.symptom
researchProduct

Premolars restored with posts of different materials: fatigue analysis

2011

Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentGlass fiberInfluence of post materialMaterials testingCrown (dentistry)Bite ForceDental MaterialsTooth FracturesFlexural strengthMaterials TestingmedicineHumansImplant denturesBicuspidComposite materialGeneral DentistryFEAFatigueTooth NonvitalCrownsImplants dentalsRestored teethStress distributionStainless SteelFinite element methodDental Prosthesis DesignDental Stress AnalysisCeramics and CompositesBiomechanical modelGlassDental materials--FatiguePrefabricated intraradicular postsMaterials dentals--FatigaDental AlloysPost and Core Technique
researchProduct

Support of removable partial dentures in situations with a unilaterally missing canine and a curved edentulous ridge.

1997

The load and movement of abutments and removable partial dentures were examined in situations with a unilaterally missing canine and a curved edentulous ridge. These measurements were performed on a model adapted to intraoral conditions. In this simulation, removable partial dentures supported by incisors may result in failure. Spring rest support results in significantly reduced articulation vertically and horizontally when compared with solid rest support and avoids periodontal overloading.

Dental Stress AnalysisCuspidDenture BasesComputer sciencemedicine.medical_treatmentDentistryDental AbutmentsIncisorDental AbutmentsmedicineMaxillaHumansRest (music)OrthodonticsAnalysis of Variancebusiness.industryJaw Edentulous PartiallyRidge (differential geometry)Denture RetentionIncisormedicine.anatomical_structureDental Stress AnalysisDenture baseDenture Partial RemovableOral SurgeryDenturesbusinessThe Journal of prosthetic dentistry
researchProduct

Investigation of the crack tip stress field in a stainless steel SENT specimen by means of Thermoelastic Stress Analysis

2019

Abstract In this work a Thermoelastic Stress Analysis (TSA) setup is implemented to investigates the Thermoelastic and Second Harmonic signals on a fatigue loaded Single Edge Notched Tension (SENT) specimen made of stainless steel AISI 304L. Three load ratios are in particular applied, R=-1, 0, 0.1. The thermoelastic signal is used to evaluate the Stress Intensity Factor via two approaches, the Stanley-Chan linear interpolation method and the over-deterministic least-square fitting (LSF) method using the Williams’ series expansion. Regarding least-square fitting, an iterative procedure is proposed to identify the optimal crack tip position in the thermoelastic maps. The SIF and T-Stress are…

Materials scienceTension (physics)02 engineering and technologyMechanicsLinear interpolation021001 nanoscience & nanotechnologyStress (mechanics)Stress fieldT-StressSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di Macchine020303 mechanical engineering & transportsThermoelastic damping0203 mechanical engineeringStress Intensity FactorHarmonicThermoelastic Stress Analysis Least Square Fitting Stress Intensity Factor Crack Closure T-StressThermoelastic Stress AnalysisLeast Square Fitting0210 nano-technologySeries expansionStress intensity factorCrack ClosureEarth-Surface Processes
researchProduct

Luting of ceramic crowns with a self-adhesive cement: Effect of contamination on marginal adaptation and fracture strength

2012

Objectives: This study evaluated the percentages of continuous margins (%CM) and fracture strength (FS) of crowns made out from blocs of leucite-reinforced ceramic (IPS Empress CAD) and luted with a representative self-adhesive cement (RelyX Unicem) under four contaminating agents: saliva, water, blood, a haemostatic solution containing aluminium chloride (pH= 0.8) and a control group with no contamination. Study Design: %CM at both tooth-cement (TC) and cement-crown (CC) interfaces were determined before and after a fatigue test consisting of 600’000 chewing loads and 1’500 temperature cycles changing from 5º C to 50º C. Load to fracture was recorded on fatigued specimens. Kruskal-Wallis t…

Dental Stress AnalysisSalivaAluminium chlorideDental CementsDentistryOdontologíaIn Vitro TechniquesDental porcelainFlexural strengthDental cementBiomaterials and Bioengineering in DentistryDentinmedicineHumansGeneral DentistryCementCrownsChemistrybusiness.industryContamination:CIENCIAS MÉDICAS [UNESCO]Dental PorcelainCiencias de la saludddc:617.6Resin Cementsmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgerybusinessmedicine.drugMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Bone-to-implant contact of orthodontic implants in humans--a histomorphometric investigation

2008

The purpose of the present study was to evaluate the percentage of direct bone-to-implant contact (BIC) of orthodontic anchorage implants (Orthosystem) after active orthodontic treatment. Twenty orthodontic implants (diameter, 3.3 mm; length, 4 or 6 mm) were inserted for orthodontic anchorage in different anatomical regions of 18 adult patients (nine males, nine females) aged 18-63 years. Fifteen implants (one per patient) were placed in the mid-palatal area, one implant (one patient) in the retromolar area of the mandible, one in the retromolar area and the mid-palatal area (one patient), and two (bilaterally, one patient) in the zygomatic area. The duration of the unloaded healing period …

AdultDental Stress AnalysisMalePalate HardAdolescentDentistryOrthodonticsOrthodontics CorrectiveOsseointegrationYoung AdultOsseointegrationOrthodontic Anchorage ProceduresmedicineHumansDevice RemovalDental ImplantsOrthodonticsWound HealingAdult patientsbusiness.industryDental Implantation EndosseousMandibleMiddle Agedmedicine.diseaseOrthodontic Anchorage ProceduresBone to implant contactRetromolar areaFemaleImplantMalocclusionbusinessMalocclusionThe European Journal of Orthodontics
researchProduct

Water diffusion and swelling stresses in highly crosslinked epoxy matrices

2016

Abstract The present work investigates the swelling induced stresses arising in two epoxy systems during water uptake. The analysed systems are two epoxy resin based on DGEBA monomer and DGEBF monomer respectively, both fully cured by DDS amine. The systems achieve different cross-link density degrees, and are characterised by high glass transition temperatures ranging between 200 and 230 °C. Both epoxies have been conditioned in deionized water baths at two different temperatures (50 °C and 80 °C). A desorption process at room temperature in a dry airborne environment was performed after saturation. Dynamic Mechanical Thermal Analysis, carried out at the various stages of hydrothermal cond…

Materials scienceEpoxy Resin; Hydrothermal Aging; Swelling; Dynamic Mechanical Thermal Analysis; Photoelastic Stress AnalysisPolymers and PlasticsDynamic Mechanical Thermal Analysi02 engineering and technology010402 general chemistry01 natural sciencesPhotoelastic Stress AnalysisStress (mechanics)DesorptionMaterials ChemistrymedicineHydrothermal AgingComposite materialThermal analysisSwellingEpoxy021001 nanoscience & nanotechnologyCondensed Matter Physics0104 chemical sciencesMechanics of MaterialsEpoxy Resinvisual_artvisual_art.visual_art_mediumSettore CHIM/07 - Fondamenti Chimici Delle TecnologieSwellingmedicine.symptomAbsorption (chemistry)0210 nano-technologyGlass transitionSaturation (chemistry)
researchProduct

Deformation analysis of ATHENA test filters made of plastic thin films supported by a mesh under differential static pressure

2019

Within ESA Cosmic Vision 2015-2025 Science Program, ATHENA was selected to be a Large-class high energy astrophysics space mission. The observatory will be equipped with two interchangeable focal plane detectors named X-Ray Integral Field Unit (X-IFU) and Wide Field Imager (WFI). In order to optimally exploit the detector sensitivity, X-ray transparent filters are required. Such filters need to be extremely thin to maximize the X-ray transparency, that is, no more than a few tens of nm, still they must be able to sustain the severe stresses experienced during launch. Partially representative test filters were made with a thin polypropylene film, coated with Ti, and supported by a thin highl…

Materials scienceOptical Profilometry Stress Analysis FEA XRay ATHENA X-IFUNumerical analysisDetectorMechanical engineeringStatic pressureDeformation (meteorology)01 natural sciencesFinite element method010309 opticsSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineFilter (large eddy simulation)Settore FIS/05 - Astronomia E AstrofisicaCardinal point0103 physical sciencesThin film010306 general physics2019 IEEE 5th International Workshop on Metrology for AeroSpace (MetroAeroSpace)
researchProduct